Plaza notes
Hard ruleDescription
Standard 18 AWG field wiring is typically sufficient for these 10 VA rated 24V actuators in zoning applications
By utilizing genuine Lochinvar boiler parts
C7009) and can be used with a Q179 for impedance matching on lead wire runs exceeding 50 feet
Can I use this for both Lochinvar and A
Running on 208/230Vac single phase power
Lochinvar & A.O. Smith 100279407 Flame Sensor 319852-301 Standard 18 AWG field wiringThe Lochinvar & A. O. Smith 100279407 Flame Sensor is a critical safety component engineered for precise flame rectification in high efficiency boilers and water heaters. This original equipment manufacturer (OEM) part is designed for rear mount installation, ensuring the control module receives an accurate microamp signal once a flame is established. When your system faces intermittent ignition lockouts or fails to sense a burner flame, replacing the
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy