Plaza notes
Hard ruleDescription
Inherent current limiting meets Class 2 requirements to protect downstream low-voltage components
Commonly selected as a direct replacement in Copeland Comfort Control systems
frequent tripping usually indicates an airflow restriction
the 60-22513-03 offers a direct-fit solution that maintains the integrity of the combustion cycle and ensures consistent ignition in residential furnace applications
Ensure the ceramic is not cracked and the wire leads are secure
Trane THT2435 Limit Switch Inherent current limiting meets ClassThe Trane THT2435 is a critical OEM replacement thermal safety component engineered for precision temperature monitoring in high performance furnaces and air handlers. Designed with a 7 inch insertion length, this automatic reset limit switch ensures superior coverage within the heat exchanger airflow. It is calibrated to professional standards, featuring a fixed setpoint that opens at 150F to interrupt the electrical circuit during over temperature