Plaza notes
Hard ruleDescription
including models SFT60 through SFT125
providing a fail-safe against overheating by interrupting the burner circuit if thresholds exceed the factory-calibrated 160°F limit
Does this board require jumpers for timing adjustments
This engages the built-in filter to provide the most stable stall voltage signal
Always verify the Full Load Amps (FLA) of your specific application
Utica-Dunkirk AC-3940-27 Inducer Motor Assembly L99H008 including models SFT60 through SFT125The Utica Dunkirk AC 3940 27 Inducer Motor Assembly is an OEM spec replacement designed to maintain optimal combustion efficiency in high efficiency Utica and Dunkirk furnaces. This 120V draft inducer is critical for venting combustion gases and ensuring that the pressure switch closes to initiate the ignition sequence. Built for a direct fit install, this assembly includes the motor and blower wheel housing, streamlined for technicians performing a